Custom Search
Flame Safe Chemical Corporation

HOME | FIRE RETARDANT COATINGS | HOW IT WORKS | CONTACT US

wood products logo 1-800-333-9197

8am-5pm (CST)

Ph: 817-740-9197

framing lumber
Dallas, Ft Worth, Austin, Houston, Corpus Christi, Wichita Falls, Abilene, Amarillo, Plano, North Dallas, El Paso, Laredo, Frisco, South Dallas, Lancaster, Dallas County, Tarrant County, Odessa, Waco, Midland, Tyler, Dallas, San Antonio,Lubbock, East Dallas, Grand Prairie, Irving, Dallas / Fort Worth metroplex, Houston area, El Paso

WOOD PRODUCTS, INC. www.flame-safe.com

Vacuum Pressure Impregnated - Kiln Dried After Treatment (KDAT) Lumber, Plywood, Timber, Shake Shingles, Architectural, Millwork, Specialty Treatments
ACCREDITED 3RD PARTING TESTING
ASTM E84 CLASS “A” - UL 723 TYPE 1 - NFPA 255 - UBC 42-1

Flame Safe Wood Products fire retardant lumber, fire retardant plywood, fire retradant timber and fire retardant wood specalties have been tested by accredited third party testing agencies. Flame Safe warrants it’s products to perform as tested and will furnish test reports upon request, in addition to those published on FLAME SAFE'S web site
Flame Safe lumber is kiln dried to a moisture content not to exceed 19%. Flame Safe plywood is kiln dried to a moisture content not to exceed 15%. Flame Safe’s finished moldings and trim is kiln dried to a maximum moisture content of 6 to 12 % depending on the species and specific use. Pitch in the wood is crystallized permitting interior and exterior finishes to be easilly applied. When kiln dried, Flame Safe fire retardant treated wood becomes lighter and stronger, maximizing it's structural uses.

flame safe logointerior logo

Interior Fire Retardant Lumber

flame safe logoxt logo

Exterior Fire Retardant Lumber

flame safe logo

Interior Fire Retardant Plywood

flame safe logoxt logo

Exterior Fire Retardant Plywood

flame safe logointerior logo

Interior Fire Retardant Timber

flame safe logoxt logo

Exterior Fire Retardant Timber

lumber with stamp

exterior plywood

timber stack

EXTERIOR FLAMEPROOF LUMBER

For those specifications that call for an exterior flame retardant lumber or plywood that will have exposure to the elements or high humidity conditions Flame Safe X-T is the product of choice.

In addition to passing the ASTM E84 Class A (UL723 Type 1)test which all exterior flame retardant lumber and plywood must pass, Flame Safe X-T will exhibit no increase in the listed classification when subjected to the standard rain test ASTM-D2898.

Flame Safe X-T has a clear finish which can be stained with a water based stain or painted with latex based paint. Flame Safe X-T is an exterior fire retardant treatment for lumber, plywood, timbers and specialty wood products. Applications such as exterior decks, balconies, stairs or siding are the notable examples of where Flame Safe X-T would be the logical choice.

PROPERTIES OF FLAME SAFE FLAME RETARDANT LUMBER and PLYWOOD

Permanence: Flame Safe exterior and interior flame retardant lumber and plywood is a permanent guard against the spread of flame

Strength: Flame Safe's aqueous based resin treatment and kiln-drying process strengthens the wood

Hygroscopicity: Flame Safe's exterior and interior flame retardant lumber and plywood is no more hygroscopic than untreated wood of any given species

Corrosion: Flame Safe exterior and interior flame retardant lumber and plywood does not demonstrate any greater corrosion rate than untreated wood on metal fasteners or hardware

Decorating and Finishing: Flame Safe exterior and interior flame retardant lumber surfaces can be stained and painted with ordinary preparation, however avoid using lacquer based stains or varnishes

Field Cuts: Flame Safe exterior and interior flame retardant wood allows the user to re-surface, mill, or rip lumber or plywood provided the exposed surfaces are coated with Flame Safe fire retardant coating (Fire Poly)

Versatility: Flame Safe exterior and interior flame retardant lumber and plywood is compatible with most waterborne preservative treatments for lumber, plywood and timber for exterior and in ground use
      
           FLAME SAFE is dedicated to setting not merely following the fireproof industry standards through ongoing research development and testing programs. FLAME SAFE continually endeavors to educate the marketplace on the significance of fireproofing combustible materials through the use of flame retardant products.

flame safe logo
Interior and Exterior
Fire Retardant Treated Plywood
flame safe logo
Interior and Exterior
Fire Retardant Treated Timbers

Softwood Plywood:
Cedar, Douglas Fir, SPF (Spruce, Pine, Fir) Redwood - typically used for construction & industrial purposes

Hardwood Plywood:
Birch - excellent strength, stiffness and resistance to creep - it has a high planar shear strength and impact resistance, which makes it especially suitable for heavy-duty floor and wall structures

Aircraft plywood:
Mahogany and/or birch - high strength plywood

Marine Plywood:
Manufactured from durable face and core veneers, with few defects so it performs longer in humid and wet conditions and resists delaminating and fungal attack - used in docks and boats

GRADE DESCRIPTION USES
A/B Face veneers practically free from all defects. Reverse veneers with only a few small knots or discolorations Stainable Cabinetry
and Wall Panels
B/C Face veneers with only a few small knots, Reverse has knots, discolorations and visible laminations Paint grade wall panels
CDX Visible knots and permitted defects roof, wall sheathing & floor decking

Fire Retardant Treated Douglas Fir, Redwood, Oak, Western Red Cedar and other species of timbers are available by special order. S4S or rough sawn available.

The use of Timbers offers aesthetic and structural benefits

 

interior wood beams2

exterior wood entry

Trusses
Braces
Herringbone Bracing Interior/Exterior
Post and Beams

Dimensions up tp 12 inches x 24 inches
Lengths up to 32 feet

Flame Safe’s fire retardant treatment maintains the Beauty of the Wood

HOME| FIRE RETARDANT COATINGS | HOW IT WORKS | CONTACT US

The information contained herein is the property of Fire Prevention Technologies d/b/a Flame Safe Chemical Corporation and Flame Safe Wood Products, Inc . © 1990 Revised 8/20/2009, Revised 2012